HF series spindle inserts run at up to 18,000+ rpm — at those speeds, the oil film is the only thing between smooth running and catastrophic bearing failure. This guide gives the exact oil change timetable for every HF type.

Vindex Industries is a textile spindle manufacturer in India exporting precision spindle inserts and bolsters to 87 countries.

Oil Change Schedule

First oil change: after 24 hours of running.
Second oil change: after 7 days.
After that: top up the oil level every 30 days.

Vindex Oil Change Timetable

StepActionWhen
1First oil change (run-in)After 24 hours of running
2Second oil changeAfter 7 days
3Oil-level check & top-upEvery 30 days

Note: the catalogue table below lists the manufacturer's maximum full oil-change intervals (5,000–10,000 operating hours depending on type and load). The 30-day oil-level check and top-up above is Vindex’s recommended level maintenance between full changes — it prevents dry running and never conflicts with the catalogue schedule.

At every oil change, coat the roller bearing thoroughly with fresh oil before putting the bolster back into service.

HF Series Oil-Change Intervals — Catalogue Reference

TypeApplication / SpeedIntervalGrade
HF 1Up to 18,000 rpm20,000 h (~28 mo)VG 10
HF 21Above 18,000 rpm12,000 h (~17 mo)VG 10
HF 33With ring & traveller15,000 h (~21 mo)VG 10
HF 35Suppressed balloon10,000 h (~14 mo)VG 68
HF 44With ring & traveller15,000 h (~21 mo)VG 10

Level Checks

Check oil level on a random sample of spindles after half the interval hours (e.g. 10,000 h for HF 1). Never run below the level mark — dry running causes overheating and twist failure.

Vindex Industries manufactures HF series spindle inserts to original dimensions in Surendranagar, Gujarat — exported to 87 countries.

Related oil-change reference

Use the combined HF and HZ spindle bolster oil-change guide to navigate the related maintenance references. Follow the selected insert and lubricant instructions for the actual service duty.

Frequently asked questions

Which HF oil-change reference should I use?

Identify the HF type and its operating-speed category in the timetable. Keep the oil-level checks described on this page in the maintenance routine.

Why should HF oil level be reviewed between changes?

A change interval and an oil-level check serve different purposes. Follow the level and condition checks specified for the actual spindle arrangement.